VOL.10

Boosting Control Valve Reliability : Isolating Structures & Remote-Type Smart Valve Positioners

Control valves often operate in tough industrial conditions. Extreme ambient heat, heavy line vibration, and corrosive air can quickly damage instrumentation and lead to frequent, costly repairs.

To build a truly reliable process loop, your positioner needs to withstand these severe environments. Choosing an advanced smart valve positioner—specifically one featuring a remote-type design or a built-in isolating structure—helps keep your plant operations running smoothly and safely.

1. High Reliability Through an Isolating Structure

In harsh plant environments, sensitive electronic components inside a smart valve positioner are vulnerable to atmospheric humidity, salt air, and corrosive gases. Additionally, pneumatic air supply lines can carry trace amounts of water or oil mist caused by upstream filter or compressor degradation.

To protect critical internal components, Azbil’s smart valve positioner uses an isolating structure that physically separates air circuit and electrical circuit:

  • Isolating Electronics : Sensitive electrical components (circuit boards, LCD screen, travel sensor) are housed inside an explosion-proof enclosure. This keeps out moisture, dust, and corrosive air.
  • Separating Air Circuits : The pneumatic air circuit sits outside the electronic chamber. If moisture or oil mist enters the supply air, it cannot reach or damage the internal electronics.
  • Safe Maintenance : Because air circuits are located outside the explosion-proof chamber, technicians can inspect and clean components (like the nozzle flapper) directly in the field without compromising explosion protection.

2. Remote-Type Positioners : Solving Severe Vibration & High-Heat Challenges

Heavy vibration from piping, fluid flow, or water hammer can quickly wear out traditional mechanical units. High ambient temperatures or hard-to-reach locations also make regular maintenance difficult and dangerous.

Our remote-type smart valve positioner solves these challenges by physically separating the positioner's main unit from the valve stem:

  • Mounting the Sensor on the Valve : Only the travel sensor adopted non-contact magnetoresistive(MR) sensor is mounted on the valve stem.
  • Placing the Main Unit Away from the valve : The main body—containing the electronics and pneumatic circuits—is mounted separately in a safe, cool, and accessible location using a connecting cable.
  • Non-Contact MR Sensor Technology : Using a non-contact MR sensor means fewer moving or sliding parts, greatly reducing wear from constant movement.
  • 5x Better Vibration Resistance : The remote smart valve positioner design withstands vibration frequencies up to 2000 Hz and acceleration up to 10 G (9.8 m/s²)—providing more than 5 times the vibration resistance of our conventional positioners.

3. Azbil’s Smart Valve Positioner Reliability & Benefits

Feature Category What It Does Why It Helps Your Plant
Isolating Structure
  • Electronics housed in an explosion-proof enclosure
  • Air circuit physically separated

Protects Against Dirty Air & Harsh Environments

Oil or water in the supply air cannot damage sensitive electronics. It also allows safe maintenance on air parts without opening the electrical cover.

Remote Type
  • Mounts only the travel sensor on the valve.
  • Places the main positioner unit in a safe, easy-to-reach area.
  • Uses a non-contact sensor with no moving parts to wear out.

Handles High Heat & Extreme Vibration

Withstands violent shaking (up to 10 G) and extreme temperatures. Protects workers by letting them perform maintenance safely at ground level.

Frequently Asked Questions (FAQ)

Q1 : How does a remote-type positioner improve vibration resistance?

Traditional positioners rely on many mechanical parts that wear down under heavy vibration. A remote-type positioner separates the main body from the valve and uses a non-contact Magnetoresistive (MR) angle sensor with fewer moving parts. This improves vibration resistance by more than 5 times than conventional positioners, withstanding acceleration up to 10 G and vibration frequencies up to 2000 Hz.

Q2 : Why is the air circuit separated from the electrical components in the isolating structure?

Instrumentation air can sometimes carry trace amounts of water or oil mist. By placing the air circuits outside the explosion-proof electronics enclosure, air contaminants cannot reach or damage the printed circuit boards or LCD screen. Additionally, technicians can clean pneumatic components like the nozzle flapper in explosive atmospheres without opening the main electronics chamber.

Q3 : What communication protocols do Azbil’s smart valve positioners support?

Azbil’s Smart Valve Positioners support industry-standard protocols including HART and FOUNDATION Fieldbus. They also support FDT/DTM technology for integration into device management software.

Q4 : How does a smart positioner help reduce energy costs in a plant?

Compared to previous models, advanced smart positioners reduce instrumentation air consumption by 20% during steady-state operation, helping plants save energy and reduce air compressor load.

Upgrade to a Reliable Smart Valve Positioner

Severe vibration, high temperatures, and harsh air quality do not have to disrupt your process. By choosing a smart valve positioner built with isolating structures and remote-mounting options, you can protect your equipment, improve plant safety, and keep maintenance simple.

Contact Azbil Technical Support

Reach out to our Azbil representative today to request a quote or schedule a technical consultation for your facility.