VOL.4

Control Valve Performance Optimization : Get Better Results from Your Existing Valves

Your Valves Can Perform Much Better

Here's a surprising fact: most control valves in industrial plants don't work as well as they could. But you may not need to buy new valves to solve this problem. Simple improvements can make a big difference.

What We See in Plants

The current situation :

  • Some have serious control problems
  • A few are badly worn but still working
  • No Maintenance (may cause sudden troubles)

What This Costs You

Even small problems add up across your plant :

Problem Area What Happens Impact on Your Plant
Energy Waste Poor control uses more electricity, steam, and fuel Higher utility bills every month
Quality Problems Temperature and flow changes affect your product More waste and customer complaints
Lower Production Your plant can't make as much as it should Lost revenue and missed targets
More Breakdowns Problems in valves stress other equipment Unexpected downtime and repairs
Higher Costs Bad valves need more repairs and parts Bigger maintenance budget needed

Easy fixes that cost very little:

  • Overhaul control valves
  • Perform positioner maintenance
  • Improve quality of air supply

Better fixes with moderate cost:

  • Add smart positioners
  • Change the valve trim
  • Replace the actuator
  • Install monitoring systems to check valve condition

Step 1 : Check How Your Valves Are Working

You need to measure performance before you can improve it.

Simple Checks You Can Do

Check Type What to Look For Why It Matters
Visual Inspection Leaks, rust, damage on valve body Shows obvious problems needing quick fix
Actuator Check Air leaks, damage, loose parts Actuator problems prevent valve from working
Positioner Condition Protection from weather, physical damage Bad positioner means poor control
Piping Setup Correct installation, no stress on valve Wrong installation causes valve problems
Valve Travel Check the difference between actual valve travel and control output Show valve and positioner problem
(stuck, damage and wiring etc.)
Process Response How temperature/pressure responds Shows if valve is working properly

Focus on Important Valves First

  • Work on valves that matter most:

Fix these valves first:

  • Valves that affect product quality
  • Valves important for safety
  • Valves that use lots of energy

Better Control Means Better Quality

When valves work better, your product quality improves and you have fewer problems.

Common Problems and Simple Solutions

Problem Why It Happens How to Fix It What You Get
Valve moves back and forth constantly Valve too big, Actuator too small, settings wrong, or sticky Change trim/actuator, adjust settings, or change packing Stable control and consistent quality
Valve responds too slowly Actuator too small, friction, or slow positioner Upgrade actuator or service the valve or adjust PID parameter of positioner or add volume booster Quick response to changes
Temperature/pressure varies too much Several things affecting valve and control Systematic improvements to fix root causes Tighter control and less waste

Quality Benefits

When you reduce temperature variation:

  • Product is more consistent
  • You make more good product
  • Less waste and rework
  • Can run at better conditions

Solve Sizing Problems Without Buying New Valves

Many valve problems come from wrong sizing. You can often fix this without replacing the whole valve.

How to Spot Sizing Problems

Is Your Valve the Wrong Size?

Valve Too Big Valve Too Small
Uses only small part of its range Uses most or all of its range
Small moves cause big flow changes Can't get enough flow when fully open
Control keeps hunting around setpoint Limits how much you can produce

Trim Changes: A Cheaper Solution

Compare Your Options:

Solution For Oversized Valves For Undersized Valves
What to Install Smaller capacity trim High-capacity trim
What It Does Reduces flow capacity Increases flow capacity
What You Keep Same valve body and connections Same valve body and connections
Cost Much less than new valve Much less than new valve
Performance Result Much better control Gets enough flow
Energy Benefit Saves energy from better control Saves energy from better control

How to Decide

Should You Optimize or Replace?

Consider Choose Trim Change/Optimization Buy Complete New Valve
Sizing Problem Moderate sizing error Severe sizing error
Valve Condition Body still in good shape Body worn out or damaged
Technology Modern enough to upgrade Very old technology
Budget Limited budget available Full budget available
Shutdown Time Short maintenance windows Longer shutdown possible
Future Plans No major changes planned Major process changes coming

Calculate savings:

  • How much energy you'll save
  • Better quality and yield
  • Less maintenance needed
  • Compare to what it costs

Most improvements pay for themselves quickly.

Add Smart Technology

Modern digital positioners can make old valves work like new ones.

Smart Positioner Benefits

What Smart Positioners Give You:

Benefit Area What You Get Why It Matters
Better Control Very accurate positioning Temperature and pressure stay stable
Fast and stable response Quick reaction to process changes
Can change how valve behaves Solve control problems without replacing valve and positioner
Automatically tunes itself No need for manual tuning
Problem Detection Watches valve all the time Catch problems before they cause downtime
Finds problems early Fix during planned maintenance
Tracks performance over time See trends and plan ahead
Helps plan maintenance Know when service is really needed
Communication Digital communication (HART, Fieldbus) Diagnose valve condition from the data
Change settings remotely No need to visit valve every time
Get data without visiting valve Save time and improve safety

Make Old Valves Last Longer

Smart positioners can extend valve life significantly:

  • Modern control features
  • Monitor condition
  • Work around wear problems
  • Delay expensive replacements

Real Results from Azbil

Azbil Thailand has helped many plants improve their valves with proven methods.

We Check Your Valves Completely

What we look at:

  • Physical condition and installation
  • How well control is working
  • If valve size is right
  • How to improve maintenance

What you get:

  • Detailed reports with recommendations
  • Comparison to best practices
  • Cost and benefit for each improvement
  • Plan for making improvements

We Help You Make Improvements

We provide:

  • Exact specifications for improvements
  • Help buying parts
  • Watch installation and startup
  • Train your team
  • Verify improvements work
  • Document all results

Keep Getting Good Results

Improvements give quick benefits, but you need ongoing work to maintain them

Keep Watching Performance

Track key numbers:

  • Important measurements for your valves
  • Regular checks and trending
  • Reviews and adjustments

Use technology:

  • Smart positioner data
  • Control system tracking
  • Automatic alerts for problems

Work with Maintenance

Fix based on condition:

  • Maintain when needed, not on schedule
  • Stop problems before they happen
  • Use resources better
  • Make parts last longer

Learn and improve:

  • Train your people
  • Use lessons for new valves
  • Build improvement culture

Start Today

Valve optimization gives real results with good financial returns. Most plants can find big opportunities through simple assessment.

Work with Azbil Thailand

Our Complete Service Package:

Service What We Do What You Get
Performance Audit Check all your valves thoroughly Detailed report with priorities
Implementation Help with installation and startup Expert guidance through the work
Training Teach your team Your people can maintain improvements
Ongoing Support Monitor and optimize continuously Sustained results over time

Why Choose Azbil Thailand:

  • Deep knowledge of valve technology since 1995
  • Experience in many industries across Thailand and Asia
  • Local support team with global company resources
  • Focus on real, measurable results you can verify
  • Proven track record with many successful projects

Take the First Step

Don't waste money on poor valve performance. Contact Azbil Thailand today for a complete valve check.

What happens next:

  1. Check Your Valves - We look at all your valves
  2. Get Improvement Plan - We tell you what to fix and how much you'll save
  3. Make Improvements - We help you do the work
  4. See Results - We measure and document improvements

Ready to make your valves work better?

Our specialists are ready to help you get real improvements.

Contact us today to learn how valve optimization
can save you money and improve your plant performance.

Click Here